FM performance classification
FIRE
WIND
HAIL
B
1-90**
1-SH*
SPECIFIC SELF-PROTECTED SYSTEM, FIRST LAYER (MATFIX OR TOPFIX FM SANDED FM) MECHANICALLY FIXED AND SECOND LAYER TORCHED. GRANULAR FINISH SLOPE <= 4.2% (1:24)
FOR NEW WORKS
SYSTEM COVERED BY
FORCE® AVIS TECHNIQUE
LOAD BEARING ELEMENT
WITH OR WITHOUT INSULATION
WATERPROOFING SYSTEM APPROVED
BY FACTORY MUTUAL FOR FLAT AREA
CONCRETE
Plain mineral wool



ROCKWOOL SA 360

or similar FM approved
ROCKWOOL panel




(ROCKWOOL INSULATION SA)
Installed by mechanical fixing


-
MATFIX® or TOPFIX® FMP sanded FM
-
FORCE® 4000 S FM


METAL
Plain mineral wool




ROCKACIER
SOUDABLE 398
or similar FM approved
ROCKWOOL panel






(ROCKWOOL INSULATION SA)
Mechanically fixed






-
MATFIX® or TOPFIX® FMP sanded FM
-
FORCE® 4000 S FM







Perlite plain

FESCO BOARD X


(MORGAN THERMAL CERAMICS DE FRANCE - SITEK)
Notes: The mechanical fixings to use are those approved by FM, i.e. either L R ETANCO or SFS STADLER.
For other components of the roof waterproofing system, see the relevant CSTB Avis Technique.
For further assistance please call our technical staff on 01 473 217514.
* Class is maximum possible ** Classification required in Western Europe