Axter Green roof - extensive

Warm roof

Listed below is a general specification using a two-layer, torcha applied system. Axter can provide written detailed specifications to suit any building on demand.

Usage Products
Deck Concrete, laid to achieve a smooth deck finish, to the correct falls and be dry before commencing installation of the waterproofing layers. An alternative is to lay the concrete flat and achieve falls with tapered insulation.
Primer Prime deck/screed with Axter's VERNIS ANTAC (see brochure) quick drying primer and allow to dry.
Vapour Control Layer High humidity building - Fully bond to the concrete deck Axter's VAP AL aluminium cored SBS modified bitumen vapour control layer.

Low humidity building - Fully bond to the concrete deck Axter's HYRANGER SPOT S3 V, an SBS modified bitumen auto-adhesive vapour control layer.

Thermal insulation Fully adhere Axter's HYTHERM ADH CFC-free surfaced insulation. Thickness will be determined by "U"-value requirements. Axter can advise on required thickness and means of adhesion.
Under layer Fully bond to the insulation Axter's HYRANGER SPOT ADH, an SBS modified bitumen auto-adhesive base layer. Care must be taken to ensure sealing of side and end laps by torching the top surface.
Top layer Fully bond by torching to the top of the under layer Axter's ALPAFLORE PY AR self finished capping sheet.
Details Both layers should be taken up the upstand and should finish at least 150 mm above finished soil level.
Rainwater outlets Rainwater outlet flanges should be encapsulated between the under layer and the top layer. It is advisable to install a paving slab or come other inspection method above all outlets so that they can be checked and regularly cleaned of detritus.
Then either:
Reservoir board Loose lay Axter's BAC CANALIS closely butted to ensure adequate support for the soil.
Filter layer Loose lay Axter's rot proof FILTER LAYER. If the membrane installer is not installing the growing medium and plants it is advised that the landscape gardener or horticultural specialist installs the BAC CANALIS and FILTER LAYER.
Growing medium and plants These will be designed and specified by the landscape gardener or horticultural specialist to meet the needs of the construction. The thickness of the growing medium will be dictated by the type of plants to be used but in general is likely to be 6 30 cm. Axter can give advice upon request.
Or:
All-in-one green roof NEW from Axter: HYDROPACK interlocking, modular pre-planted trays.

In general specifications should follow the guidelines given in:

British Standard Code of Practice BS 6229:2003, Flat roofs with continuously supported coverings.

British Standard Code of Practice BS 8217:2004, Flexible bitumen sheet roofing.

Specifications are given for roof slopes< 5°. Apply to Axter for further information.

Axter advises that an AXTERSHIELD INSTALLER, who has specialist knowledge of Axter's systems, installs the specification given below and from whom extended guarantees can be obtained.

Specifications listed are for guidance only and Axter cannot be held responsible for any errors or omissions. It is the specifier's responsibility to ensure that the specifications are suitable for the requirements of his construction.

Website copyright ©2008 Axter (UK) Limited