AXTER ROOF WATERPROOFING AND INSULATION SPECIFICATION

Supporting deck Existing waterproofing
Application Two-layer waterproofing with insulation
System reference FORCE LINE

Existing waterproofing with added thermal insulation
Two layer waterproofing

Reinforced bitumen membranes should only be applied over a continuous substrate which provides full support. Substrate Materials used to form the roof deck in flat roofs should be those listed in BS 6229:2003 Flat roofs with continuously supported coverings – Code of practice and conform to the relevant requirements in BS 8217:2005 Reinforced bitumen membranes – Code of practice.

The waterproofing system should conform to the requirements of British Standard 8747:2007 Reinforced Bitumen membranes (RBMs) for roofing – Guide to selection and specification and be installed in accordance with British Standard BS 8217:2005.

Supporting deck Existing membrane or asphalt waterproofing system
Deck preparation Ensure substrate is sound, cut and seal all blisters, remove details. Prime all surfaces with a suitable bituminous primer and allow to dry in accordance with Annex C of British Standard BS 6229:2003.
Vapour control layer Existing waterproofing will act as the vapour control layer.
Thermal insulation PIR rigid foamed boards
Waterproofing system Base layer THERMECRAN
  Intermediate layer FORCE LINE 3 VV
  Cap sheet FORCE LINE 4.5 RE
  SP classification S4P3
Details FORCE LINE 4.5 RE
Finishes Self protected system

Product substitution

  • The two layers, THERMECRAN and FORCE LINE 3 VV, can be replaced by a single layer of HYRANGER SPOT ADH self adhesive membrane. In which case the thermal insulation must have a coated glass fibre surface such as EL 3000 from CELOTEX or TR 27 from Kingspan.
  • FORCE LINE 4.5 RE can be replaced by FORCE LINE 4 RE.

NBS specification

Please view the Axter NBS specification for further information.

Notes

All membrane products torch applied except THERMECRAN which is loose laid.